Choose your product
Narrow your results
Filter by product attributes
Process Chromatography (44)
Added to Shopping Cart
Item no.
311.5118-2
Inner Diameter
6.7 mm
Brand
CIMmultus®
Ligand
Multimodal (anion exchange-hydrogen bonding)
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
Item no.
311.6157-2
Inner Diameter
6.7 mm
Brand
CIMmultus®
Ligand
SO3 (strong cation exchanger, sulfonate)
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
Item no.
311.8136-2
Inner Diameter
6.7 mm
Brand
CIMmultus®
Ligand
C4 HLD (hydrophobic, butyl – high ligand density)
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
Item no.
1014.6157-2
Inner Diameter
255 mm
Brand
CIMmultus®
Ligand
SO3 (strong cation exchanger, sulfonate)
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
Item no.
1014.8136-2
Inner Diameter
255 mm
Brand
CIMmultus®
Ligand
C4 HLD (hydrophobic, butyl – high ligand density)
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
Item no.
1014.5113-2
Inner Diameter
255 mm
Brand
CIMmultus®
Ligand
QA (strong anion exchanger, quaternary amine)
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
Item no.
1014.5114-2
Inner Diameter
255 mm
Brand
CIMmultus®
Ligand
DEAE (Weak anion exchanger, diethylamino)
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
Item no.
1014.1219-2
Inner Diameter
255 mm
Brand
CIMmultus®
Ligand
Oligo dT18 coupled to CDI-activated matrix, C12 Linker
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
Item no.
1014.1218-2
Inner Diameter
255 mm
Brand
CIMmultus®
Ligand
Oligo dT18 coupled to CDI-activated matrix, C6 Linker
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
Item no.
311.5114-2
Inner Diameter
6.7 mm
Brand
CIMmultus®
Ligand
DEAE (Weak anion exchanger, diethylamino)
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
Item no.
311.1219-2
Inner Diameter
6.7 mm
Brand
CIMmultus®
Ligand
Oligo dT18 coupled to CDI-activated matrix, C12 Linker
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
Item no.
311.5114-1.3
Inner Diameter
6.7 mm
Brand
CIMmultus®
Ligand
DEAE (Weak anion exchanger, diethylamino)
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
Item no.
311.1218-2
Inner Diameter
6.7 mm
Brand
CIMmultus®
Ligand
Oligo dT18 coupled to CDI-activated matrix, C6 Linker
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
Item no.
311.5113-2
Inner Diameter
6.7 mm
Brand
CIMmultus®
Ligand
QA (strong anion exchanger, quaternary amine)
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min