Sartolon Sartoscale Disposable
Sartolon filters are designed for broad chemical compatibility for specific applications in the pharmaceutical and chemical industry. The double-layer design leads to superior filtration performance compared to other nylon membrane filters and thereby allows more economical design of your filtration process. Sartolon filter elements are ideal for filtration of a broad range of solvents and solvent-containing liquids.
- Item No.:
- 5105307HS--FF--M
*Custom/bulk order quotes are provided within 72 hours of request.
Sterilizing-Grade, 0.2 µm Rated FiltersSartolon Pore size: 0.45 | 0.2 µm (heterogeneous Polyamide double layer)Your Benefits:
- High chemical compatibility for the filtration of solvents
- High filter capacity by in-built pre-filter (double-layer construction)
- Excellent performance for oily formulations
- Highly economic solution e.g. for antibiotics processes
Compliance Information
-
Bacterial Endotoxins< 0.18 EU/mL as determined by the LAL test
-
Biological ReactivityAll materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
-
ExtractablesThe total amount of extractables is well below the limits established by the current USP unter "Sterile Water for Injection".
-
GMP ComplianceThis product was manufactured in conformance with established Current Good Manufacturing Practice (cGMP) standards.
Dimensions
-
Filtration Area17.3 cm²
General Specifications
-
Minimum Required Bubble Point3.0 bar | 43.5 psi
Materials of Construction
-
Housing MaterialPolypropylene (PP)
-
Membrane MaterialNylon (NY)
Operating Conditions
-
Maximum Differential Pressure20 °C: 5 bar; 80 °C: 2 bar
Physicochemical Information
-
Non-Fiber ReleasingThis filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
Product Information
-
BrandSartolon
-
Filter TypeFlat disc Capsules
-
TypeSterile filter
Usage Protocols
-
Sterilization ProceduresAutoclaving: 1 cycle at max. 134 °C, 2 bar | 29 psi, 30 min.