Choose your product

  • Shop
  • Chromatography

Narrow your results

Most used filters

Filter by product attributes

Chromatography (570)

  • CIMmultus® DEAE 4000 mL Monolithic Column (2 μm)
    Item no.
    1014.5114-2
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Application
    Preparative Applications
  • CIMmultus® Oligo dT18 (C12 Linker) 800 mL cGMP (2 μm)
    Item no.
    921.1219-2
    Bed Volume
    800 mL
    Column Tube Length
    150 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C12 Linker
    Application
    Preparative Applications
  • CIMmultus® Oligo dT18 (C6 Linker) 4 mL Monolithic Column (2 μm)
    Item no.
    414.1218-2
    Bed Volume
    4 mL
    Column Tube Length
    28 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C6 Linker
    Application
    Preparative Applications
  • CIMmultus® DEAE 400 mL Monolithic Column (2 μm)
    Item no.
    814.5114-2
    Bed Volume
    400 mL
    Column Tube Length
    75 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Application
    Preparative Applications
  • CIMmultus® Oligo dT18 8000 mL Monolithic Column (2 μm)
    Item no.
    1011.1219-2
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C12 Linker
    Application
    Preparative Applications
  • CIMmultus® SO3 4 mL Monolithic Column (2 μm)
    Item no.
    414.6157-2
    Bed Volume
    4 mL
    Column Tube Length
    28 mm
    Ligand
    SO3 (strong cation exchanger, sulfonate)
    Application
    Preparative Applications
  • CIMmultus® Oligo dT18 (C6 Linker) 400 mL cGMP (2 μm)
    Item no.
    924.1218-2
    Bed Volume
    400 mL
    Column Tube Length
    75 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C6 Linker
    Application
    Preparative Applications
  • CIMmultus® DEAE 4 mL Monolithic Column (2 μm)
    Item no.
    414.5114-2
    Bed Volume
    4 mL
    Column Tube Length
    28 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Application
    Preparative Applications
  • CIMmultus® Oligo dT18 (C6 Linker) 80 mL Monolithic Column (2 μm)
    Item no.
    611.1218-2
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C6 Linker
    Application
    Preparative Applications
  • CIMmultus® SO3 8 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    901.6157-2
    Bed Volume
    8 mL
    Column Tube Length
    56 mm
    Ligand
    SO3 (strong cation exchanger, sulfonate)
    Application
    Preparative Applications
  • CIMmultus® C4 HLD 400 mL Monolithic Column (2 μm)
    Item no.
    814.8136-2
    Bed Volume
    400 mL
    Column Tube Length
    75 mm
    Ligand
    C4 HLD (hydrophobic, butyl – high ligand density)
    Application
    Preparative Applications
  • CIMmultus® C4 HLD 800 mL Monolithic Column (2 μm)
    Item no.
    811.8136-2
    Bed Volume
    800 mL
    Column Tube Length
    150 mm
    Ligand
    C4 HLD (hydrophobic, butyl – high ligand density)
    Application
    Preparative Applications
  • CIMmultus® DEAE 800 mL cGMP Compliant (6 μm)
    Item no.
    921.5114-6
    Bed Volume
    800 mL
    Column Tube Length
    150 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Application
    Preparative Applications
  • CIMmultus® DEAE 400 mL cGMP Compliant (2 μm)
    Item no.
    924.5114-2
    Bed Volume
    400 mL
    Column Tube Length
    75 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Application
    Preparative Applications
  • CIMmultus® SO3 1 mL Monolithic Column (2 μm)
    Item no.
    311.6157-2
    Bed Volume
    1 mL
    Column Tube Length
    4.2 mm
    Ligand
    SO3 (strong cation exchanger, sulfonate)
    Application
    Preparative Applications
  • Results per page: | |