Microbial enumeration membrane filters

For reliable water, beverage and environmental testing

Membrane filtration is a well-established and widely accepted technique for microbial enumeration in routine and regulatory microbiological testing. Sartorius offers mixed cellulose esters (MCE/CN), cellulose acetate (CA) and polyethersulfone (PES) membrane filters, commonly available as 47mm discs for testing of drinking and bottled water, surface and process water, beverages, cosmetics, environmental and pharmaceutical samples. 

Shop Membrane FiltersContact an Expert

Types of membranes for microbial enumeration

CN/MCE membrane filters 

The microbiological reference standard

Suitable for environmentally stressed bacteria commonly encountered in drinking and surface water testing, and for routine microbial enumeration across a wide range of standard culture media.

 Mixed cellulose esters (CN/MCE) filters remain the benchmark for membrane filtration microbiology. Their symmetrical pore structure and naturally hydrophilic surface promote excellent wetting and uniform microorganism distribution. CN/MCE membrane filters are valued for their high recovery rates. Low adsorption characteristics and strong visual contrast between colonies and membrane surface make CN/MCE membrane filters well suited for routine microbial enumeration across a wide range of standard culture media.

CA membrane filters

Enhanced purity and sensitivity

Suitable for process water, cosmetic testing, and environmental monitoring, where sample matrices may contain disinfectants or organic residues.

 Cellulose acetate (CA) filters offer high flow rates and thermal stability and build on the advantages of cellulose-based filters while offering reduced extractables and lower adsorption of potentially inhibitory substances. The smooth, uniform surface supports consistent colony development and reliable microbial recovery of sensitive microorganisms.

PES membrane filters

Robust performance for challenging samples

Suitable for beverage testing, industrial process water, and environmental applications where both durability and microbiological performance are required.

  Polyethersulfone (PES) filters combine high mechanical strength with broad chemical compatibility. Their asymmetric pore structure enables higher flow rates, particularly when filtering more complex or particulate-rich samples. When optimized for microbiological applications, PES membrane filters deliver strong recovery while maintaining robustness under demanding conditions.

Shop membrane filters

Microsart®️ e.motion Membrane Filters - product image of stack of five filters

Sterile single-packed membrane filters

Biosart membranes

Sterile Microsart® e.motion dispenser-ready membrane filters

Non-sterile membrane filters (Bulk)

Why choose Sartorius membrane filters?

Cellulose Nitrate Membrane filter to Agar transfer - application image close view
Proven expertise in membrane filtration

Sartorius’ expertise in membrane filtration dates back to 1927 and is rooted in the pioneering membrane research of Nobel Prize laureate Richard Zsigmondy. Sartorius played a key role in translating membrane filters into practical tools for retaining particles, bacteria and other microorganisms. Decades of experience ensure reliable, high-quality membrane filters for water, beverage, cosmetic, and environmental testing.

Optimized for both retention and recovery

Sartorius’ membrane filters are engineered not only to retain microorganisms at defined pore sizes, but also to support high recovery and colony growth. This balance is essential for accurate enumeration and compliance with microbiological standards such as ISO 7704:2023 , where growth performance on the membrane filter is as critical as filtration efficiency. Purpose-build and ISO 7704:2023 certified  0.45 µm High Flow membrane filters support superior recoveries.

See Why Microbial Recovery Matters

Versatile formats to suit your testing needs

Available as individually sterile-packed membrane filters or in a convenient Microsart® e.motion dispenser pack, designed for high-throughput testing with minimal reloading, ideal for laboratories handling large sample volumes.  The membrane filters are also available as sterile and non-sterile versions.

Flexible solutions for any application

A broad range of membrane material types, pore sizes, colors, and grids to suit different samples, microbes, and colony counting methods.

Gridded membrane filters facilitate manual enumeration by dividing the surface into defined counting zones, reducing operator variability. Colored membrane filters enhance contrast for specific microorganisms or media types, improving visualization and accuracy. Ungridded membrane filters are preferred for automated colony counting systems, where grid lines may interfere with image-analysis algorithms.

Enabling effective microbial recovery through reliable membrane filtration

By allowing microorganisms to be concentrated from defined sample volumes and subsequently cultured directly on the membrane filter surface, membrane filtration delivers high sensitivity, quantitative results, and strong alignment with international testing standards.

While pore size and retention are essential, microbial recovery is the true measure of membrane filter performance in microbiological analysis. International standards such as ISO 7704:2023 emphasize that membrane filters must support the growth of retained microorganisms at recovery rates comparable to reference methods. This principle is reinforced across relevant water testing standards including ISO 8199:2018,  ISO 11133:2014  and application-specific methods such as ISO 9308-1:2014  and ISO 7899-2:2000.

What to consider when selecting a membrane filter

Poor recovery can result in underestimated counts and compromised data integrity in membrane filtration microbiology. Membrane material, surface chemistry, thickness, and wettability all directly influence the ability of stressed or slow-growing microorganisms to form visible colonies. Selecting the right membrane filter, and the right supplier, is therefore critical for compliant and reproducible results when using the membrane filter technique.

Accurate microbial enumeration is the result of aligning multiple parameters: sample type, membrane material, membrane colour and grid design, target microorganisms, and culture media. The apparent simplicity of membrane filtration conceals this complexity, and underscores why membrane quality, recovery performance, and application expertise are essential.

icon-coach

Need help selecting a membrane filter?

Get answers to any questiosn you have about Sartorius membrane filters and selection.

Contact a Membrane Filter Expert Now

Membrane filter resources and documentation

Application Note

Microbiological performance testing of membrane filters

Performance testing of membrane filters in accordance with EN ISO 7704:2023 used for water quality testing

EN ISO thumbnail
User Guide

New EN ISO 7704:2023 at a glance

Requirements for the performance testing of membrane filters and media used for direct enumeration of microorganisms by culture methods

Application Note

Enumeration of Clostridium perfringens

Microbiological performance testing of membrane filters in accordance with EN ISO 7704:2023

Female scientist pouring clear liquid into a funnel for microbiological testing - in lab application image
Brochure

Regulatory landscape in environmental water quality control

Product documentation

Datasheet

Microsart® e.motion membrane filters

PDF | 255.5 KB

Frequently asked questions

Recovery of microorganisms is a critical consideration because membrane filtration is not just about retaining microorganisms, but ensuring that they can grow and form colonies for accurate enumeration. High retention without good recovery can lead to underestimated microbial counts, misleading water quality or environmental assessments, and non-compliance with standards such as ISO 7704.

Factors that influence microbial recovery include:

  • Membrane Material: Hydrophilic membrane filters like cellulose nitrate (CN), cellulose acetate (CA), or polyethersulfone (PES) support colony growth better than hydrophobic membrane filters. Surface chemistry affects how bacteria adhere and how nutrients diffuse.
  • Pore Size and Structure: Pores must be small enough to trap the target microorganisms without causing stress or damage. Symmetrical vs. asymmetric pore structures can also impact microbial recovery.
  • Chemical Compatibility: Residual disinfectants, solvents, or sample matrix components can inhibit growth. Choosing a membrane filter compatible with your sample ensures higher recovery.
  • Membrane filter Handling and Pre-treatment: Proper wetting, sterilization, and handling prevent stress to microbes and support consistent growth.
  • Culture Conditions: Recovery also depends on the medium, incubation time, and temperature. Some microorganisms are sensitive to stress or nutrient limitations and require optimized growth conditions.

Membrane filtration in microbiological testing is a method where a liquid sample is passed through a microporous membrane that traps microorganisms on its surface, then the membrane is placed on a growth medium so the microbes form visible colonies that can be counted or identified.

The productivity ratio indicates how effectively a membrane filter supports the growth of microorganisms it retains. According to ISO 7704:2023 and ISO 11133:2014, a ratio of 0.5 means that at least 50% of the microorganisms grow on the membrane filter compared to a non-selective reference medium, such as a spread plate, under the same conditions.

This ratio is important because it ensures that the membrane filter not only retains microorganisms, but also supports their growth for accurate microbial enumeration. Membrane filters with low productivity ratios may underestimate microbial counts, leading to unreliable results and potential regulatory non-compliance.

In practical terms, a productivity ratio of 0.5 sets a minimum standard for microbial recovery.

For most microbiology membrane filtration work, the standard choice is a sterile mixed cellulose ester (MCE) membrane with a 0.45 µm pore size. This is the most widely used option for routine microbial recovery and enumeration, especially for water, beverages, and general microbiological quality control. Gridded Cellulose Nitrate (Mixed Cellulose Ester) 0.45 µm High Flow are the best fit to the standard microbiology membrane filter choice.

For most microbiological testing, especially membrane filtration methods used on water or other liquid samples, 0.45 µm is not only the best default and regulatory recommended choice.

0.45 µm: the standard choice for routine microbial recovery, enumeration, water testing, and many microbiology QC methods

0.22 µm: used for sterilizing filtration, where the goal is to remove microorganisms from a liquid rather than recover them for counting

0.8 µm or higher: used when faster flow is needed or when the sample has more particles, but they are less suitable for retaining small bacteria than 0.45 µm

If recovery is unexpectedly low, start by changing pore size to 0.45 µm (or High Flow), then check for potential inhibitors that may interfer with growth promotion, media type, incubation conditions and vaccum stress.