Choose your product

  • Shop
  • Chromatography

Narrow your results

Most used filters

Filter by product attributes

Chromatography (71)

  • CIMmultus® QA 40 mL Monolithic Column (2 μm)
    Item no.
    614.5113-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    40 mL
    Column Tube Length
    55 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
  • CIMmultus® QA 8 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    901.5113-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    8 mL
    Column Tube Length
    56 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
  • CIMmultus® HiP2 Plasmid Process Pack® 8-8 mL
    Item no.
    100.0012-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    8 mL
    Column Tube Length
    56 mm
    Application
    Preparative Applications
  • CIMmultus® SO3 40 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    914.6157-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    40 mL
    Column Tube Length
    55 mm
    Ligand
    SO3 (strong cation exchanger, sulfonate)
  • CIMmultus® QA 80 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    911.5113-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
  • CIMmultus® Oligo dT18 (C6 Linker) 8 mL Monolithic Column (2 μm)
    Item no.
    411.1218-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    8 mL
    Column Tube Length
    56 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C6 Linker
  • CIMmultus® Oligo dT18 (C12 Linker) 4 mL Monolithic Column (2 μm)
    Item no.
    414.1219-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    4 mL
    Column Tube Length
    28 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C12 Linker
  • CIMmultus® HiP2 Plasmid Process Pack® 80-80 mL
    Item no.
    100.0013-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Application
    Preparative Applications
  • CIMmultus® HiP2 Plasmid Process Pack® 40-40 mL cGMP Compliant
    Item no.
    101.0017-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    40 mL
    Column Tube Length
    55 mm
    Application
    Preparative Applications
  • CIMmultus® SO3 80 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    911.6157-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Ligand
    SO3 (strong cation exchanger, sulfonate)
  • CIMmultus® HiP2 Plasmid Process Pack® 40-40 mL
    Item no.
    100.0017-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    40 mL
    Column Tube Length
    55 mm
    Application
    Preparative Applications
  • CIMmultus® Oligo dT18 (C6 Linker) 80 mL cGMP (2 μm)
    Item no.
    911.1218-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C6 Linker
  • CIMmultus® HiP2 Plasmid Process Pack® 4-4 mL
    Item no.
    100.0016-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    4 mL
    Column Tube Length
    28 mm
    Application
    Preparative Applications
  • CIMmultus® HiP2 Plasmid Process Pack® 80-80 mL cGMP Compliant
    Item no.
    101.0013-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Application
    Preparative Applications
  • CIMmultus® Oligo dT18 (C12 Linker) 8 mL Monolithic Column (2 μm)
    Item no.
    411.1219-2
    Maximum Operating Pressure
    2.0 MPa | 20 bar | 290 psi
    Bed Volume
    8 mL
    Column Tube Length
    56 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C12 Linker
  • Results per page: | |