  • CIMmultus® Oligo dT18 (C12 Linker) 4000 mL Monolithic Column (2 μm)
    Item no.
    1014.1219-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
  • CIMmultus® Oligo dT18 (C12 Linker) 8000 mL cGMP (2 μm)
    Item no.
    931.1219-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
  • CIMmultus® Oligo dT18 (C6 Linker) 8000 mL cGMP (2 μm)
    Item no.
    931.1218-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
  • CIMmultus® DEAE 8000 mL cGMP Compliant (2 μm)
    Item no.
    931.5114-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
  • CIMmultus® Oligo dT18 (C6 Linker) 8000 mL Monolithic Column (2 μm)
    Item no.
    1011.1218-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
  • CIMmultus® HiP2 Plasmid Process Pack® 8000-8000 mL
    Item no.
    100.0015-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
  • CIMmultus® Oligo dT18 8000 mL Monolithic Column (2 μm)
    Item no.
    1011.1219-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
  • CIMmultus® SO3 4000 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    934.6157-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
  • CIMmultus® Oligo dT18 (C12 Linker) 4000 mL cGMP (2 μm)
    Item no.
    934.1219-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
  • CIMmultus® Oligo dT18 (C6 Linker) 4000 mL Monolithic Column (2 μm)
    Item no.
    1014.1218-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
  • CIMmultus® QA 8000 mL Monolithic Column (2 μm)
    Item no.
    1011.5113-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
  • CIMmultus® QA 8000 mL cGMP Compliant  Monolithic Column (2 μm)
    Item no.
    931.5113-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
  • CIMmultus® C4 HLD 4000 mL Monolithic Column (2 μm)
    Item no.
    1014.8136-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
  • CIMmultus® DEAE 4000 mL cGMP Compliant (2 μm)
    Item no.
    934.5114-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
  • CIMmultus® QA 4000 mL Monolithic Column (2 μm)
    Item no.
    1014.5113-2
    Inner Diameter
    255 mm
    Maximum Operating Pressure
    0.7 MPa | 7 bar | 100 psi
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
  • Results per page: | |