Skip to content Skip to navigation menu

Flexsafe® 2D Bags

Proven Flexsafe® 2D Pre-Designed Solutions (PDS) have been designed for all bioprocessing fluids storage or sampling like media, buffer, harvest & downstream intermediates, drug substance and drug product. Flexsafe® bags benefit from outstanding assurance of quality supply, robustness, closure integrity and excellent cell growth performance. The versatile range of Flexsafe® PDS from 20mL to 50L allows for sterile filtration, storage, transfer and shipping of all biopharmaceutical fluids in all process steps. You can rely on Flexsafe® to provide safe and convenient storage for your most critical drug substances and drug products.

 

Choose your product

Products (51)

STD Flexsafe® 3L (MPC/TC)
Item no.
FLS130163
Process Step
Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
3 L
Inlet Line
3/8" MPC Female + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/4" Tri-Clamp sanitary flange with gasket, cap and union + 3/8" ID Silicone (Tuflux® SIL) 0.3 m (12") + Clipster® in a separate pouch
STD Flexsafe® 5L (Sartopore® XLG/TC)
Item no.
FLS130019
Process Step
Cell Harvest & Downstream Processing Intermediates
Volume
5 L
Filter Type
Sartopore® 2 Midicaps® (size 4)
Inlet Line
Sartopore® 2 XLG 0.8 | 0.2 µm + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 5L (Sartopore® XLG/MPC)
Item no.
FLS130018
Process Step
Media Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
5 L
Filter Type
Sartopore® 2 Midicaps® (size 4)
Inlet Line
Sartopore® 2 XLG 0.8 | 0.2 µm + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 50L (TC/TC)
Item no.
FLS130192
Process Step
Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
50 L
Inlet Line
3/4" Tri-Clamp sanitary flange with gasket, cap and union + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/4" Tri-Clamp sanitary flange with gasket, cap and union + 3/8" ID Silicone (Tuflux® SIL) 0.3 m (12") + Clipster® in a separate pouch
STD Flexsafe® 50L (OPTA/OPTA)
Item no.
FLS130156
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
50 L
Inlet Line
3/8" Opta® SFT Female + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" Opta® SFT Male + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 50L (OPTA/MPC)
Item no.
FLS130148
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
50 L
Inlet Line
3/8" Opta® SFT Female + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" MPC Male + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 3L (MPC/MPC)
Item no.
FLS130145
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
3 L
Inlet Line
3/8" MPC Female + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" MPC Male + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 3L (MPC/OPTA)
Item no.
FLS130153
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
3 L
Inlet Line
3/8" MPC Female + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" Opta® SFT Male + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 50L (MPC/TC)
Item no.
FLS130164
Process Step
Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
50 L
Inlet Line
3/8" MPC Female + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/4" Tri-Clamp sanitary flange with gasket, cap and union + 3/8" ID Silicone (Tuflux® SIL) 0.3 m (12") + Clipster® in a separate pouch
STD Flexsafe® 3L (OPTA/TC)
Item no.
FLS130165
Process Step
Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
3 L
Inlet Line
3/8" Opta® SFT Female + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/4" Tri-Clamp sanitary flange with gasket, cap and union + 3/8" ID Silicone (Tuflux® SIL) 0.3 m (12") + Clipster® in a separate pouch
STD Flexsafe® 3L (OPTA/OPTA)
Item no.
FLS130155
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
3 L
Inlet Line
3/8" Opta® SFT Female + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" Opta® SFT Male + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 3L (OPTA/MPC)
Item no.
FLS130147
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
3 L
Inlet Line
3/8" Opta® SFT Female + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" MPC Male + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 3L (TC/TC)
Item no.
FLS130191
Process Step
Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
3 L
Inlet Line
3/4" Tri-Clamp sanitary flange with gasket, cap and union + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/4" Tri-Clamp sanitary flange with gasket, cap and union + 3/8" ID Silicone (Tuflux® SIL) 0.3 m (12") + Clipster® in a separate pouch
STD Flexsafe® 50L (Sartopore® XLG/OPTA)
Item no.
FLS130143
Process Step
Media Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
50 L
Filter Type
Sartopore® 2 Midicaps® (size 7)
Inlet Line
Sartopore® 2 XLG 0.8 | 0.2 µm + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 50L (MPC/MPC)
Item no.
FLS130146
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
50 L
Inlet Line
3/8" MPC Female + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" MPC Male + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 50L (MPC/OPTA)
Item no.
FLS130154
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
50 L
Inlet Line
3/8" MPC Female + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" Opta® SFT Male + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 50L (OPTA/TC)
Item no.
FLS130166
Process Step
Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
50 L
Inlet Line
3/8" Opta® SFT Female + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/4" Tri-Clamp sanitary flange with gasket, cap and union + 3/8" ID Silicone (Tuflux® SIL) 0.3 m (12") + Clipster® in a separate pouch
STD Flexsafe® 20L (Sartopore® XLG/OPTA)
Item no.
FLS130036
Process Step
Media Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
20 L
Filter Type
Sartopore® 2 Midicaps® (size 7)
Inlet Line
Sartopore® 2 XLG 0.8 | 0.2 µm + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 5L (OPTA/MPC)
Item no.
FLS130042
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
5 L
Inlet Line
3/8" Opta® SFT Female + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" MPC Male + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
STD Flexsafe® 5L (MPC/MPC)
Item no.
FLS130039
Process Step
Media Preparation, Buffer Preparation, Cell Harvest & Downstream Processing Intermediates
Volume
5 L
Inlet Line
3/8" MPC Female + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Outlet Line
3/8" MPC Male + Sealing Cap + 3/8" ID TPE (C-Flex®) 0.5 m (20") + Clipster® in a separate pouch
Results per page: | |

Building on more than 20 years of experience in designing single-use solutions, we have developed the bioprocessing solutions with their adapted quality control levels able to support all fluid handling and transportation steps for drug manufacturing.

Assurance of Quality Supply

  • Control of the entire process from the resins to final products enhances assurance of supply & change control

Cell growth

  • Optimization of resin formulation and establishment of the film extrusion design space provide excellent and reproducible cell growth

E | L Profile

  • Controls on variability of raw materials and of manufacturing process ensure consistent extractable profiles

Robustness & Ease of Use

  • Product robustness is validated in the entire design space and demonstrated with most stringent ASTM shipping test
  • Self-deploying bag for ease of use

Closure Integrity

  • Best Assurance of Integrity with a combination of tests at supplier & at point-of-use

Brochure

Flexsafe® — New PE film. New Benchmark.
en 1.8 MB
Flexsafe® 2D & 3D Pre-Designed Solutions for Storage and Shipping
en 19.4 MB

Datasheet

Configurable Flexsafe® 2D Bags - From 20 mL to 50 L
en 537.2 kB