Skip to content Skip to navigation menu

Mycap® Bottle Closures

One-piece, ready-to-use and single-use aseptic fluid transfer system for bottles.

 

Choose your product

Products (71)

Mycap® for 250mL Glass Bottle; GL45 Thread

Mycap® with GL45 threads fits onto popular glass 250mL bottles.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with plug and dip tube optimized for 100mm tall bottles (eg, Corning® Pyrex® Round Media, Duran® Protect, etc).

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure C-Flex® tubing.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Ready for installation, autoclave and use.

Mycap® for Media; 6 x 500mL Square PETG Bottle

Sterile filter media directly into manifold of six 500mL Square PETG Bottle through pre-attached Sartopore® 2 Filter.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Aseptically connect filled bottle at point-of-use by tube welding (C-Flex® 1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD).

Individually double bagged, gamma irradiated and ready for use.

Mycap® for Media; 500mL Square PETG Bottle

Sterile filter media directly into 500mL Square PETG Bottle through pre-attached Sartopore® 2 Filter.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Aseptically connect filled bottle at point-of-use by tube welding (C-Flex® 1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD).

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 2000mL Square PETG Bottle

Mycap® on 2L Nalgene® PETG Square Media Bottle.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with plug and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure C-Flex® tubing.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 1000mL Square PETG Bottle

Mycap® on 1L Nalgene® PETG Square Media Bottle.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with plug and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure C-Flex® tubing.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 50mL Polypropylene Centrifuge Tube

Mycap® on 50mL Falcon® Polypropylene Conical Tube.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with plug and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure C-Flex® tubing.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 50mL Polypropylene Centrifuge Tube

Mycap® on 50mL Falcon® Polypropylene Conical Tube.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with plug and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure C-Flex® tubing.

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 125mL Square PETG Bottle

Mycap® on 125mL Nalgene® PETG Square Media Bottle.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with plug and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure C-Flex® tubing.

Quickly and simply disconnect filter with QUICKSEAL® aseptic disconnect.

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 250mL Square PETG Bottle

Mycap® on 250mL Nalgene® PETG Square Media Bottle.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with capped male luer fitting and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure silicone tubing.

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 1000mL Square PETG Bottle

Mycap® on 1L Nalgene® PETG Square Media Bottle.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with capped male luer fitting and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure silicone tubing.

Individually double bagged, gamma irradiated and ready for use.

Mycap® for Media; 6 x 500mL Square PETG Bottle

Sterile filter media directly into manifold of six 500mL Square PETG Bottle through pre-attached Sartopore® 2 Filter.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Aseptically connect filled bottle at point-of-use by pre-attached aseptic connector (Aseptiquik® S) or tube welding (C-Flex® 1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD).

Individually double bagged, gamma irradiated and ready for use.

Mycap® for Media; 6 x 500mL Square PETG Bottle

Sterile filter media directly into manifold of six 500mL Square PETG Bottle through pre-attached Sartopore® 2 Filter.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Aseptically connect filled bottle at point-of-use by pre-attached aseptic connector (Aseptiquik® S).

Individually double bagged, gamma irradiated and ready for use.

Mycap® for 100mL Glass Bottle; GL45 Thread

Mycap® with GL45 threads fits onto popular glass 100mL bottles.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with plug and dip tube optimized for 100mm tall bottles (eg, Corning® Pyrex® Round Media, Duran® Protect, etc).

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure C-Flex® tubing.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Ready for installation, autoclave and use.

Mycap® Assembly; 500mL Square PETG Bottle

Mycap® on 500mL Nalgene® PETG Square Media Bottle.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with capped male luer fitting and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure silicone tubing.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 50mL Polypropylene Centrifuge Tube

Mycap® on 50mL Falcon® Polypropylene Conical Tube.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with capped male luer fitting and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure silicone tubing.

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 250mL Square PETG Bottle

Mycap® on 250mL Nalgene® PETG Square Media Bottle.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with capped male luer fitting and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure silicone tubing.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Individually double bagged, gamma irradiated and ready for use.

Mycap® for Media; 6 x 250mL Square PETG Bottle

Sterile filter media directly into manifold of six 250mL Square PETG Bottle through pre-attached Sartopore® 2 Filter.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Aseptically connect filled bottle at point-of-use by tube welding (C-Flex® 1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD).

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 15mL Polystyrene Centrifuge Tube

Mycap® on 15mL Falcon® Polystyrene Conical Tube.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with plug and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure C-Flex® tubing.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Individually double bagged, gamma irradiated and ready for use.

Mycap® Assembly; 2000mL Square PETG Bottle

Mycap® on 2L Nalgene® PETG Square Media Bottle.

Air vent port with 0.2µm hydrophobic PES membrane filter. Inlet|outlet port with capped male luer fitting and dip tube to bottom for complete fluid withdraw.

1/8″ID x 1/4″ OD|3.2mm ID x 6.4mm OD platinum-cure silicone tubing.

Individually double bagged, gamma irradiated and ready for use.

Mycap® for Media; 1000mL Square PETG Bottle

Sterile filter media directly into 1000mL Square PETG Bottle through pre-attached Sartopore® 2 Filter.

Quickly and simply disconnect filter with Quickseal® aseptic disconnect.

Aseptically connect filled bottle at point-of-use by pre-attached aseptic connector (Aseptiquik® S).

Individually double bagged, gamma irradiated and ready for use.

Results per page: | |

Sartorius' Mycap® Bottle Closures make aseptic fluid transfer into and out of bottles simple and reliable.

Ready To Use

Mycap® is preassembled, ready to use and single-use. Integral tubing with useful connection options makes aseptic fluid handling in bottles simple. Save time and improve process by skipping cleaning and assembly.

Universal Closure

All Mycap® have our robust, plasticizer-free platinum-cured silicone seal. Silicone is well recognized as the high-performance closure resin preventing contaminants from getting in and maintaining a microbial barrier across a wide temperature range including autoclave. Mycap® feature the same seal regardless of bottle type, tubing size, tubing type or port configuration making it simple to validate one and use Mycap® anywhere in your drug production process—Mycap® is the first universal closure system.