Skip to content Skip to navigation menu

CIMac™

CIMac™ Analytical Columns combine all elaborate characteristics of CIM monoliths at analytical scale and are your perfect tool for analysis and control of manufacturing processes, ideal for process analytical technology (PAT). Designed for fast and reproducible HPLC monitoring and quantitation of proteins, viruses, pDNA, and other large biomolecules, they allow you to achieve rapid, high-resolution and flow-independent separations in a matter of minutes.

   

Choose your product

Products (10)

CIMac™ QA 0.1 mL Analytical Column (1.3 µm)
Brand
CIMac™
Ligand
QA (strong anion exchanger, quaternary amine)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Length
4.95 mm
CIMac™ AAV full/empty 0.1 mL Analytical Column (1.3 µm)
Brand
CIMac™
Ligand
QA modified for AAV (strong anion exchanger, quaternary amine)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Length
4.95 mm
CIMac™ pDNA 0.3mL Analytical Column (1.4 µm)
Brand
CIMac™
Ligand
DEAE (weak anion exchanger, diethylamino)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 0.67 – 10 CV/min
Length
15 mm
CIMac™ SO3 0.1 mL Analytical Column (1.3 µm)
Brand
CIMac™
Ligand
SO3 (strong cation exchanger, sulfate)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Length
4.95 mm
CIMac™ Adeno 0.1 mL Analytical Column (2 µm)
Brand
CIMac™
Ligand
QA modified for Adeno (strong anion exchanger, quaternary amine)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Length
4.95 mm
CIMac™ EDA 0.1 mL Analytical Column (2 µm)
Brand
CIMac™
Ligand
EDA (weak anion exchanger, ethylene diamino)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Length
4.95 mm
CIMac™ DEAE 0.1 mL Analytical Column (1.3 µm)
Brand
CIMac™
Ligand
DEAE (weak anion exchanger, diethylamino)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Length
4.95 mm
CIMac™ r-Protein A 0.1 mL Analytical Column (2 µm)
Brand
CIMac™
Ligand
r-Protein A (affinity, recombinant protein A produced from E. Coli coupled to CDI-preactivated support)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Length
4.95 mm
CIMac™ EDA 0.1 mL Analytical Column (1.3 µm)
Brand
CIMac™
Ligand
EDA (weak anion exchanger, ethylene diamino)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Length
4.95 mm
CIMac™ QA 0.1 mL Analytical Column (6 µm)
Brand
CIMac™
Ligand
QA (strong anion exchanger, quaternary amine)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Length
4.95 mm
Results per page: | |

CIMac™ Analytical Columns were primarily designed for the in-process and final control of various samples at different stages of the purification process. They can be operated at high volumetric flow rates (from 1 to 20 column volumes/min); therefore, the information about the product quantity and purity can be obtained within a few minutes.