Skip to content Skip to navigation menu

Choose your product

Show more

Anion Exchange Monolith (20)

CIMac™ EDA 0.1 mL Analytical Column (1.3 µm)
Bed Volume
0.1 mL
Ligand
EDA (weak anion exchanger, ethylene diamino)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Channel Size
1.3 µm
CIMac™ QA 0.1 mL Analytical Column (6 µm)
Bed Volume
0.1 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Channel Size
6 µm
CIMac™ Adeno 0.1 mL Analytical Column (2 µm)
Bed Volume
0.1 mL
Ligand
QA modified for Adeno (strong anion exchanger, quaternary amine)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Channel Size
2 µm
CIMac™ EDA 0.1 mL Analytical Column (2 µm)
Bed Volume
0.1 mL
Ligand
EDA (weak anion exchanger, ethylene diamino)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Channel Size
2 µm
CIMac™ DEAE 0.1 mL Analytical Column (1.3 µm)
Bed Volume
0.1 mL
Ligand
DEAE (weak anion exchanger, diethylamino)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Channel Size
1.3 µm
CIMac™ QA 0.1 mL Analytical Column (1.3 µm)
Bed Volume
0.1 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Channel Size
1.3 µm
CIMac™ AAV full/empty 0.1 mL Analytical Column (1.3 µm)
Bed Volume
0.1 mL
Ligand
QA modified for AAV (strong anion exchanger, quaternary amine)
Flow Rate
0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min
Channel Size
1.3 µm
CIMmultus® DEAE 8000 mL Monolithic Column (2 μm)
Bed Volume
8000 mL
Ligand
DEAE (Weak anion exchanger, diethylamino)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® QA 8000 mL Monolithic Column (6 μm)
Bed Volume
8000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® QA 8000 mL Monolithic Column (2 μm)
Bed Volume
8000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® QA 8000 mL Monolithic Column (1.3 μm)
Bed Volume
8000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® QA 4000 mL Monolithic Column (2 μm)
Bed Volume
4000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® DEAE 4000 mL Monolithic Column (2 μm)
Bed Volume
4000 mL
Ligand
DEAE (Weak anion exchanger, diethylamino)
Inner Diameter
255 mm
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® DEAE 8000 mL cGMP Compliant (6 μm)
Bed Volume
8000 mL
Ligand
DEAE (Weak anion exchanger, diethylamino)
Inner Diameter
255 mm
Flow Rate
1000–16000 mL/min | 15–270 cm/h | 0.15–2 CV/min
CIMmultus® QA 4000 mL cGMP Compliant (2 μm)
Bed Volume
4000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
Results per page: | |