Skip to content Skip to navigation menu

Choose your product

Show more

Anion Exchange Monolith (18)

CIMmultus® DEAE 8000 mL cGMP Compliant (6 μm)
Bed Volume
8000 mL
Ligand
DEAE (Weak anion exchanger, diethylamino)
Inner Diameter
255 mm
Flow Rate
1000–16000 mL/min | 15–270 cm/h | 0.15–2 CV/min
CIMmultus® QA 4000 mL cGMP Compliant (2 μm)
Bed Volume
4000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® DEAE 8000 mL cGMP Compliant (2 μm)
Bed Volume
8000 mL
Ligand
DEAE (Weak anion exchanger, diethylamino)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® QA 8000 mL cGMP Compliant (1.3 μm)
Bed Volume
8000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® QA 8000 mL cGMP Compliant (6 μm)
Bed Volume
8000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® QA 8000 mL cGMP Compliant (2 μm)
Bed Volume
8000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® DEAE 4000 mL cGMP Compliant (2 μm)
Bed Volume
4000 mL
Ligand
DEAE (Weak anion exchanger, diethylamino)
Inner Diameter
255 mm
Flow Rate
500–4000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® DEAE 1 mL Monolithic Column (2 μm)
Bed Volume
1 mL
Ligand
DEAE (Weak anion exchanger, diethylamino)
Inner Diameter
6.7 mm
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
CIMmultus® DEAE 8000 mL Monolithic Column (2 μm)
Bed Volume
8000 mL
Ligand
DEAE (Weak anion exchanger, diethylamino)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® DEAE 1 mL Monolithic Column (1.3 μm)
Bed Volume
1 mL
Ligand
DEAE (Weak anion exchanger, diethylamino)
Inner Diameter
6.7 mm
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
CIMmultus® QA 8000 mL Monolithic Column (6 μm)
Bed Volume
8000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
CIMmultus® QA 1 mL Monolithic Column (2 μm)
Bed Volume
1 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
6.7 mm
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
CIMmultus® QA 1 mL Monolithic Column (1.3 μm)
Bed Volume
1 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
6.7 mm
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
CIMmultus® QA 1 mL Monolithic Column (6 μm)
Bed Volume
1 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
6.7 mm
Flow Rate
1–16 mL/min | 40–625 cm/h | 1–16 CV/min
CIMmultus® QA 8000 mL Monolithic Column (2 μm)
Bed Volume
8000 mL
Ligand
QA (strong anion exchanger, quaternary amine)
Inner Diameter
255 mm
Flow Rate
1000–8000 mL/min | 15–135 cm/h | 0.15–1 CV/min
Results per page: | |