CIMac™ Analytical Columns combine all elaborate characteristics of CIM monoliths at analytical scale and are your perfect tool for analysis and control of manufacturing processes, ideal for process analytical technology (PAT). Designed for fast and reproducible HPLC monitoring and quantitation of proteins, viruses, pDNA, and other large biomolecules, they allow you to achieve rapid, high-resolution and flow-independent separations in a matter of minutes.

See more Products below

*Custom/bulk order quotes are provided within 72 hours of request.

Choose your product

Products (10)

  • CIMac™ EDA 0.1 mL Analytical Column (1.3 µm)
    Item no.
    110.5116-1.3
    Ligand
    EDA (weak anion exchanger, ethylene diamine)
    Channel Size
    1.3 µm
    Bed Volume
    0.1 mL
  • CIMac™ QA 0.1 mL Analytical Column (6 µm)
    Item no.
    110.5113-6
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Channel Size
    6 µm
    Bed Volume
    0.1 mL
  • CIMac™ pDNA 0.3mL Analytical Column (1.4 µm)
    Item no.
    150.8501-1.4
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Channel Size
    1.4 µm
    Bed Volume
    0.3 mL
  • CIMac™ SO3 0.1 mL Analytical Column (1.3 µm)
    Item no.
    110.6157-1.3
    Ligand
    SO3 (strong cation exchanger, sulfonate)
    Channel Size
    1.3 µm
    Bed Volume
    0.1 mL
  • CIMac™ Adeno 0.1 mL Analytical Column (2 µm)
    Item no.
    110.8502-2
    Ligand
    QA modified for Adeno (strong anion exchanger, quaternary amine)
    Channel Size
    2 µm
    Bed Volume
    0.1 mL
  • CIMac™ r-Protein A 0.1 mL Analytical Column (2 µm)
    Item no.
    110.1004-2
    Ligand
    r-Protein A (affinity, recombinant protein A produced from E. Coli coupled to CDI-preactivated support)
    Channel Size
    2 µm
    Bed Volume
    0.1 mL
  • CIMac™ QA 0.1 mL Analytical Column (1.3 µm)
    Item no.
    110.5113-1.3
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Channel Size
    1.3 µm
    Bed Volume
    0.1 mL
  • CIMac™ AAV full/empty 0.1 mL Analytical Column (1.3 µm)
    Item no.
    110.8503-1.3
    Ligand
    QA modified for AAV (strong anion exchanger, quaternary amine)
    Channel Size
    1.3 µm
    Bed Volume
    0.1 mL
  • CIMac™ EDA 0.1 mL Analytical Column (2 µm)
    Item no.
    110.5116-2
    Ligand
    EDA (weak anion exchanger, ethylene diamine)
    Channel Size
    2 µm
    Bed Volume
    0.1 mL
  • CIMac™ DEAE 0.1 mL Analytical Column (1.3 µm)
    Item no.
    110.5114-1.3
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Channel Size
    1.3 µm
    Bed Volume
    0.1 mL
  • CIMac™ Analytical Columns were primarily designed for the in-process and final control of various samples at different stages of the purification process. They can be operated at high volumetric flow rates (from 1 to 20 column volumes/min); therefore, the information about the product quantity and purity can be obtained within a few minutes.

    Product Information

    • Brand
      CIMac™