Skip to content Skip to navigation menu

Minisart® RC25 Syringe Filter 17764----------K, 0.2 µm Regenerated Cellulose

Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17764 with a pore size of 0.2 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.

Item no.:  17764----------K

Price:  $123.00

Availability:  For more information please log in

50 Pieces
   

Non-sterile Minisart® RC syringe filters are supplied in a pouch in one pack. This reduces waste and makes the handling easier whenever the application allows clarification under non-sterile conditions, like this is the case for the majority of sample preparation steps prior to HPLC or GC analysis. The RC membrane is the best option for reliable and leachable free filtration. The very low non-specific binding characteristics of this membrane makes it a perfect choice for aqueous samples and solvents. In addition, unlike PVDF filters, those with RC membranes are suitable for DMSO and other amides, or for ketones, esters, and ethers. The housing of the filter is made of PP (polypropylene) which is compatibility with harsh solvents, acids and bases.

  • A pouch in one pack for less waste
  • Minimum extractables or leachables
  • Very low non-specific binding
  • Outperforming chemical compatibility

Brochure

Minisart® Syringe Filters — The Easy Choice – Clean and Safe (US and Canada)
en 13.0 MB
Шприцевые насадки Minisart® — Лёгкий выбор, высокая степень чистоты и надёжности
ru 2.7 MB
宣传手册:实验室过滤产品精简目录
zh 19.0 MB

Catalog

Laboratory Filtration Products
en 8.2 MB

Flyer

Minisart® Syringe Filters for HPLC Sample Preparation
en 479.9 kB
Шприцевые насадки Minisart® для пробоподготовки перед ВЭЖХ
ru 630.8 kB
The Advantages of Minisart® Hydrophilic Syringe Filters for HPLC Sample Preparation
en 728.7 kB
Minisart® RC Syringe Filters for HPLC Sample Preparation — RC versus PVDF used with Methanol and Acetonitrile
en 514.5 kB
Преимущества шприцевых насадок Minisart® с гидрофильными мембрана- ми для подготовки проб перед ВЭЖХ
ru 795.3 kB
Minisart® RC шприцевые насадки для пробоподготовки перед ВЭЖХ — Сравнение регенерированной целлюлозы и ПВДФ для фильтрации метанола и ацетонитрила
ru 575.0 kB

User Manual

HPLC-Certificate — Minisart® Syringe Filters for Sample Preparation – reliable and ultrapure
en 364.1 kB
Directions for Use - Minisart®-RC | SRP | NY | PES
en 1.6 MB
Minisart® Chemical Compatibility Guide
en 229.3 kB

Dimensions

  • Filter Diameter
    ⌀ 25 mm
  • Filtration Area
    4.8 cm²
  • Housing Dimensions
    33 × 24 mm

General Specifications

  • Filter Paper/Membrane Color
    White (opaque)
  • Flow Rate
    80 mL/min with water at 1 bar (14.5 psi) | 160 mL/min with methanol at 1 bar (14.5 psi)
  • Total Throughput
    Up to 100 mL
  • pH Range
    3.0 – 14.0

Operating Conditions

  • Maximum Allowable Working Temperature
    121 °C (250 °F)
  • Maximum Operating Pressure
    4.5 bar (65 psi)
  • Operating Pressure
    4.5 bar (65 psi)

Volumes

  • Hold-up Volume
    100 – 200 µL before bubble point

eShop Dynamic Attributes

  • Application
    • HPLC
    • LCMS
    • ICPMS
    • Buffer & Media
  • Application Area
    • Analytical Sample Preparation
    • Clarification
  • Biosafety
    All materials of this filter element meet the requirements of the current USP Biological Reactivity tests for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
  • Bubble Point
    Min. value with water 3.0 bar (44 psi)
  • Burst Pressure
    Min. value 7.0 bar (102 psi)
  • Connector Inlet
    Female Luer Lock
  • Connector Outlet
    Male Luer Slip
  • Cytotoxicity
    According to ISO 10993-5
  • Delivery Condition
    Non-Sterile
  • Device Type
    Syringe Filters
  • Extractables
    HPLC certified
  • High Flow
    No
  • Housing Material
    Polypropylene (PP)
  • Membrane Material
    Regenerated cellulose (RC)
  • Non-Fiber Releasing
    This filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
  • Pack Size
    50
  • Packaging
    Bulk pouch packed
  • Pore Size
    0.2 µm
  • Sample Type
    • Aqueous
    • Solvents
    • Harsh liquids according to chemical compatibility
  • Sterilization Method
    • Ethylene oxide
    • Gamma irradiation
    • Autoclave
  • Sterilization Procedures
    • Ethylene oxide
    • Gamma irradiation
    • Autoclave, 121°C, 30 min
  • Wettability
    Hydrophilic

Customers Also Purchased

Minisart® RC15 Syringe Filter 17761----------K, 0.2 µm Regenerated Cellulose

Minisart® RC15 Syringe Filter 17761----------K, 0.2 µm Regenerated Cellulose

Learn More
Minisart® RC25 Syringe Filter 17764----------S, 0.2 µm Regenerated Cellulose

Minisart® RC25 Syringe Filter 17764----------S, 0.2 µm Regenerated Cellulose

Learn More
Minisart® RC25 Syringe Filter 17764----------Q, 0.2 µm Regenerated Cellulose

Minisart® RC25 Syringe Filter 17764----------Q, 0.2 µm Regenerated Cellulose

Learn More
Minisart® NY25 Syringe Filter 17845----------Q, 0.2 µm Polyamide (Nylon)

Minisart® NY25 Syringe Filter 17845----------Q, 0.2 µm Polyamide (Nylon)

Learn More
Minisart® RC15 Syringe Filter 17761----------Q, 0.2 µm Regenerated Cellulose

Minisart® RC15 Syringe Filter 17761----------Q, 0.2 µm Regenerated Cellulose

Learn More