Vivaflow® 50 Complete System, 115v

Complete set of accessories for the Vivaflow® 50 with a 115 V pump

Comprises: Pump (115 V), Easy Load pump head (size 16), tubing, 500 ml sample| diafiltration reservoir, module stand, pressure indicator, T-connectors, series interconnectors

Price (USD):
$2,300.00
Item No.: 
VFS504
Availability: 
Piece
1

*Custom/bulk order quotes are provided within 24 hours of request.

Vivaflow® 50 is a disposable and ready-to-use crossflow cassette for filtration and concentration of samples from 100 ml to 3 l. The membrane surface per device is 50 cm2. One pack contains two devices and comes with all necessary accessories for running two devices with a laboratory pump and a size 16 pump head. For speeding up the concentration and increasing the volume throughput, six cassettes can be connected.

Optimally suited for applications like cell culture supernatant concentration, virus concentration and water concentration e.g. in fish breading facilities, this economical product offers a standard of ease of use, reliability and flexibility unrivalled by any laboratory filtration system in the market. The thin-channel, flip-flow recirculation path of the modules provides high crossflow velocities with minimum pump speed requirements. A single 50 cm² module typically reduces 500 ml to 15 ml in less than 50 min. Nearly total recovery of the concentrate is achieved with a single rinse. Up to six of the unique interlocking modules can be connected for easy scale up resulting in a capacity of several liters. Vivaflow® 50 is intended for single use. All accessories for sample concentration, except a peristaltic pump with a pump head for size 16 tubing, are included in the package. A 500 ml sealed diafiltration reservoir can be added to the system for rapid and convenient buffer exchange.

Pump(115V), Pump head (size 16), tubing, 500ml sample/diafiltration reservoir

Equipment required

The standard Vivaflow® 50 package comes with two cassettes, tubing, flow restrictor, one series interconnector and high pressure pump tubing. All you need is a peristaltic pump with a pump head capable of handling 6.4 mm OD tubing (size 16).

Running more than two Vivaflow® 50 devices in parallel and series

For speeding up the concentration, as many as six Vivaflow® 50 cassettes can easily be connected using 2 T-connectors for connecting 2 Vivaflow® cassettes at the inlet and at the outlet and series interconnectors for connecting the devices inbetween. A pressure indicator needs to be built in the inlet for optimal control.

  • High flow rate and recovery
  • Clear housing for process monitoring
  • Ready to use single cassettes
  • Easy set up of multiple cassette
  • Economical and disposable product

Unique in its performance

A single 50cm2 module will typically reduce 500 ml to less than 15 ml in under 50 minutes. Less than 10 ml minimum system recirculation for highest concentrations. Less than 1.5 ml non recoverable hold up volume. Near total recoveries achievable with a single 10 ml rinse.

Compliance Information

  • Animal Components
    No  
  • CSA Compliant
    Yes  
  • Certification
    None  
  • Electrical / Battery item
    Yes  

Materials of Construction

  • Material o-ring | seal
    Silicone (SI)  

Operating Conditions

  • Maximum Allowable Working Temperature
    60 °C (140 °F)  
  • Maximum Operating Pressure
    3 bar (44 psi)  

Power Requirements

  • Line Voltage
    115 V  

Product Information

  • Brand
    Vivaflow®  
  • Flow Restrictors, 0.6 mm, 6pc

    $12.20

    Flow restrictor 0.6 mm (6 pieces)

    Flow restrictors 6 x 0.6 pink to be used with the Vivaflow® systems

  • T-Connectors, Size 16, 2pc

    $12.20

    T Connectors for Vivaflow® 50 (2 pieces)

    T connectors for running 2 stacks of Vivaflow® 50

  • Pressure Indicator, 1-3 bar

    $50.90

    Pressure Indicator (1-3 bar)

    Pressure indicator (1-3 bar) for Vivaflow® units

  • Replacement Tubing Set for Vivaflow®

    $101.00

    Tubing Set for Vivaflow® 50

    Comprises: 2 x 1 m size 16 PVC tubing with inlet fittings, 2 x 50 cm size 16 PVC tubing with 0.6 mm flow restrictors, 1 x series interconnector

  • Luer Fittings, Female to Size 16 Hose Barb, 10pc

    $12.20

    Female Luer fittings Size 16 (10 pieces) to be used with the Vivaflow® systems

  • Peristaltic Pump Drive, 115v

    $1,250.00

    Pumps used for filtration. Choose from a broad range of universal pumps and manual pumps over laboratory vacuum pumps to peristaltic pumps.

  • Cassette Stand for Vivaflow® 50

    $255.00

    Plate used for setting up Vivaflow® 50 units

    Vivaflow® 50 stand

  • Sample and Diafiltration Reservoir, 500 mL

    $227.00

    500 ml sample|diafiltration reservoir to be used with Vivaflow® systems. Allows the convenient application of samples and the continuous replacement of buffer.

  • Series Interconnectors, Size 16, 6pc

    $25.50

    Series Interconnectors (6 pieces)

    Series interconnectors for running up to six Vivaflow® 50 units in parallel

  • Peristaltic Load Pump Head, Size 16

    $648.00

    Masterflex Easy Load Pump Head - Size 16