text.skipToContent text.skipToNavigation

Sartolon® Cartridge

Sartolon filters are designed for broad chemical compatibility for specific applications in the pharmaceutical and chemical industry. The double-layer design leads to superior filtration performance compared to other nylon membrane filters and thereby allows more economical design of your filtration process. Sartolon filter elements are ideal for filtration of a broad range of solvents and solvent-containing liquids.

Order Number:  5102707H2

Availability:  On Request

Sterilizing-Grade, 0.2 µm Rated Filters

Sartolon
Pore size: 0.45 | 0.2 µm (heterogeneous Polyamide double layer)

Your Benefits:

  • High chemical compatibility for the filtration of solvents
  • High filter capacity by in-built pre-filter (double-layer construction)
  • Excellent performance for oily formulations
  • Highly economic solution e.g. for antibiotics processes

For highest process flexibility all Sartolon filters are available for conventional or single use applications. All filter elements are available in various sizes and adapter combinations. Please review the selection guide in the supporting resources literature.

Datasheet

Sartolon ® 0,2 µm Cartridges & Midicaps & MaxiCaps
en 619.8 kB

Product properties

  • Capsule/Cartridge Format
    Cartridges
  • Filter Size
    20" (1.2 m² / 12.9 ft²)
  • Material prefilters
    Nylon (NY)
  • Connector Outlet
    Bayonet Adapter with 222 Double O-ring (27)
  • Connector Inlet
    Bayonet Adapter with 222 Double O-ring (27)
  • Filtration area
    1.2 m²
  • Pore size pre-filter
    0.45 µm
  • Pore size final-filter
    0.2 µm
  • Outer diameter
    70 mm
  • Material o-ring | seal
    Silicone (SI)
  • Vent Valve
    N/A

Technical attributes

  • Sterilization Procedures
    In-Line Steam Sterilization=== at 134 °C, 20 min., 0.5 bar, min. 25 Cycles` Autoclaving=== at 134°C, 30 min, 2 bar, min. 25 Cycles
  • Industry
    Pharma/Biotech
  • Sterilization Method
    Autoclavable & In-Line Steam Sterilizable
  • Bacterial Endotoxins
    < 0.25 EU/mL as determined by the LAL test
  • Bacterial Retention
    Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
  • GMP Compliance
    This product was manufactured in conformance with established Current Good Manufacturing Practice (cGMP) standards.
  • Maximum Differential Pressure
    20 °C=== 5 bar; 80 °C=== 2 bar
  • Biosafety
    All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
  • Extractables
    The total amount of extractables is well below the limits established by the current USP unter "Sterile Water for Injection".
  • Non-Fiber Releasing
    This filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
  • Housing material
    Polypropylene (PP)
  • Support Fleece
    Polypropylene (PP)
  • Min. required Bubble Point
    3.0 bar
  • Max. Allowable Back Pressure (at 20°C)
    2 bar / 29 psi at 20°C; 1 bar / 14.5 psi at 80°C
  • Max. diffusion
    26 mL/min at 2.5 bar | 36 psi
  • Application
    Filtration of antibiotics and organic solvents