Skip to content Skip to navigation menu

Hamilton ML630 complete package

The Hamilton Microlab® 600 series dispenser is a highly precise syringe pump designed to quickly and easily dilute and dispense fluids. This positive displacement system provides better than 99% accuracy, independent of a liquid’s viscosity, vapor pressure, and temperature. The inert fluid path minimizes sample carryover and is compatible with harsh chemicals.

Item no.:  YDU-10

Availability:  On Request

Automated liquid handling with highest accuracy (± 0.1%) and precision (± 0.2%)
High-performance 48.000 step per stroke syringe drive

  • high-accuracy aspiration and dispensing of fluids
  • high-precision in handling even very small volumes, as well as volatile, viscous, and dense liquids
  • solvent volume based on sample weight: assures accuracy and precision reducing expensive analytes use and solvent waste
  • Chemically inert: Fluid path made of borosilicate glass, PTFE and CTFE resistant to harsh solvents

Closed fluid path

  • no contamination risk
  • cost-effective: no expensive glassware, no costly cleaning and decontamination necessary

SCAT solvent safety kit ensures safe use of solvents without user exposure

Please select from the following accessories to complete the dispenser:

  • 69Y03295 Serial RS232 cable for connecting the dispenser to Cubis MSA balances
  • YDO01MS-R Additional serial interface for parallel operation of printer and dispensing unit on Cubis MSA balances
  • YAPP16 Dosing application for controlling the dispenser for the automatic production of standards
  • YDU-20 SD card for storing data when using software application YAPP16

Application Note

Cubis®Individual with Q-App for Standard Preparation
en 2.6 MB

Product properties

  • Dimensions
    177.8 × 139.7 × 266.7 mm
  • Weight
    5.9 kg
  • Volume
    1.0 μL – 50 mL

Technical attributes

  • Storage temperature
    -20 – 70 °C
  • Test Certificates and Approvals
    CE, CSA Installation category I and Pollution degree 2
  • Relative Humidity
    20 – 90% (non-condensing)
  • Power Requirements (Primary)
    100 – 240 V 1.5A max 50 – 60 Hz
  • Additional Product Specifications
    • Accuracy: 1% ≤ Stroke < 5% 3.0%
    • SPrecision: 1% ≤ Stroke < 5% 1.5%
    • Syringe size: 10, 25, 50 ml
    • Syringe drive mechanism: 1.8° stepper motor with variable volumetric flow rate
    • Fluid path: Borosilicate, PTFE, CTFE
    • Rated power: 24 VDC, 2.5A
  • Compliance
    FCC Part 15, Class B EMC: EN 61326-1, Class B
  • Gross Weight
    7.7 kg
  • Maximum Ambient Temperature